MicroMag 2900/3900 Data File (Series 0016.002)
Remanence curves:  DCD

INSTRUMENT
Configuration                   VSM
Temperature control             None
Hardware version                0004
Software version                01/29/2013
Units of measure                Hybrid SI
Temperature in                  Kelvin

SAMPLE
Mass                            N/A
Volume                          N/A
Demagnetizing factor            N/A

SETTINGS
Field range                     N/A
Field (command)                 N/A
Moment range                   +1.000000E-03
Averaging time                 +100.0000E-03
Temperature (command)           N/A
Tmprtr difference correction    No
Orientation                     0.000000E+00
Vibration amplitude             1.0
Calibration factor             +5.019859E+00
Operating frequency            +83.00000E+00

MEASUREMENT
Description                    ""
Field (measured)                N/A
Temperature (measured)          N/A
Averages (completed)            N/A
Measured on                     09/05/2023  15:33
Elapsed time                   +98.25800E+00

PROCESSING
Background subtraction          No
Delta-m processing              No
Demagnetizing factor            No
Normalization                   No
Normalization factor            N/A
Offset (field)                  No
Offset (moment)                 No
Pole saturation                 No
Slope correction                No

VIEWPORT
Left                           -100.0000E-03
Right                          +100.0000E-03
Bottom                         -1.000000E-03
Top                            +1.000000E-03
Show X-axis?                    Yes
Show Y-axis?                    Yes

CHARACTERIZATION
Initial slope                   N/A
Saturation                      N/A
Remanence                      +28.65971E-06
Coercivity (direct)             N/A
Coercivity (remanent)          +27.03992E-03
S* (direct)                     N/A
S* (DCD)                       -68.87087E-03

SCRIPT
Include IRM?                    No
Include DCD?                    Yes
Include direct moment?          No
Demagnetize before measuring?   No
Field sequence                  Nonlinear
Initial (non-zero) field       +10.00000E-06
Final field                    +100.0000E-03
Number of points/curve          30
Pause at applied field         +100.0000E-03
Slew rate to applied field     +1.000000E+00
Averaging time                 +100.0000E-03
Saturating field               +100.0000E-03
Pause at saturating field      +1.000000E+00
Saturating field applied        Only once
Slew rate to saturating field  +1.000000E+00
Pause at zero field            +100.0000E-03
Slew rate to zero field        +1.000000E+00
Number of segments              1
Number of data                  30

Segment   Averaging      Initial        Field         Final                    Final 
 Number      Time         Field       Increment       Field         Pause      Index 
             (s)           (T)           (T)           (T)           (s)     
0000001,+100.0000E-03, 0.000000E+00,+10.00000E-06,-100.0000E-03,+100.0000E-03,0000030

                           
    Field       Remanence  
     (T)          (Am)    
+605.0917E-09,+28.65971E-06
-10.72616E-06,+28.63325E-06
-23.80714E-06,+28.62046E-06
-41.42130E-06,+28.60569E-06
-63.25880E-06,+28.59142E-06
-93.71783E-06,+28.58256E-06
-134.4269E-06,+28.56090E-06
-187.0116E-06,+28.51684E-06
-257.2078E-06,+28.47805E-06
-348.9595E-06,+28.41594E-06
-471.3748E-06,+28.33595E-06
-631.8443E-06,+28.22496E-06
-844.6241E-06,+28.07064E-06
-1.126149E-03,+27.86416E-06
-1.498217E-03,+27.61092E-06
-1.988674E-03,+27.24200E-06
-2.638111E-03,+26.74953E-06
-3.491305E-03,+26.09290E-06
-4.623532E-03,+25.17614E-06
-6.117030E-03,+23.91557E-06
-8.097372E-03,+22.11527E-06
-10.71227E-03,+19.42452E-06
-14.15808E-03,+15.30122E-06
-18.71512E-03,+9.472131E-06
-24.73622E-03,+2.271167E-06
-32.69460E-03,-5.574824E-06
-43.20987E-03,-13.36347E-06
-57.09433E-03,-20.25948E-06
-75.41592E-03,-25.48981E-06
-99.69889E-03,-28.67890E-06

MicroMag 2900/3900 Data File ends